Medium Voltage Submarine Cable

Бүтээгдэхүүний тайлбар

The XLPE Insulated & Sheathed 3 core submersible cables that we deal in are ideal for usage in submersible pumps in deep wells for irrigation (Direct Burial), drinking water supply, industries, mines, fountains.

Бүтээгдэхүүний төрөл: , Tags: ,

Бүтээгдэхүүний дэлгэрэнгүй тайлбар

Application:

These submarine cables are used for power transmission to offshore islands, oil platforms or to cross-rivers and lakes.

Cable design based on the mayor national or international standards e.g. VDE, IEC and ICEA or according to customers design and standards.

Standard:

IEC 60228; IEC 60502;IEC 60840; IEC 62067

Construction:

1. Conductor: Copper conductor, circular stranded compacted, water blocked.

2. Conductor Screening: Extruded semi-conductive compound.

3. Insulation: XLPE.

4. Insulation Screening: Extruded semi-conductive compound.

5. Waterproof Layer: Semi-conductive waterproof tape

6. Screen: Copper wires and copper helix, swelling powder.

7. Laminated Core Sheath: Al. laminated tape bonded to overlaying

8. PE sheath

9. Fillers: Polypropylene filler.

10. Fibre-Optic Element: Fibre optic cable.

11. Separator: Binder tapes.

12. Bedding Layer: Polypropylene strings.

13. Armour: Galvanized steel wires.

14. Serving: Hessian Tapes, bituminous compound, polypropylene strings.

Electrical Data:

6/10(12)KV

Nominal Cross Section Area Capacitance Inductance Current Rating
mm² μF/mm mH/km A
35 0.23 0.43 167
50 0.26 0.41 199
70 0.29 0.38 241
95 0.32 0.37 288
120 0.35 0.35 327
150 0.38 0.34 363
185 0.42 0.33 405
240 0.47 0.32 464

12/20(24)KV

Nominal Cross Section Area Capacitance Inductance Current Rating
mm² μF/mm mH/km A
35 0.17 0.47 171
50 0.18 0.44 199
70 0.2 0.41 243
95 0.22 0.4 292
120 0.24 0.38 328
150 0.26 0.37 364
185 0.28 0.35 408
240 0.31 0.34 467

18/30(36) KV

Nominal Cross Section Area Capacitance Inductance Current Rating
mm² μF/mm mH/km A
50 0.14 0.48 202
70 0.15 0.45 245
95 0.17 0.42 291
120 0.18 0.41 330
150 0.19 0.39 366
185 0.21 0.38 411
240 0.23 0.36 470

Dimension and Weight

6/10(12) KV

Nominal Cross Section Area Nominal Conductor Diameter Nominal Insulation Thickness Nominal Screen Cross Section Area Nominal Core Sheath Thickness Nominal Core Diameter Nominal Bedding Thickness Nominal Steel Wire Diameter Serving Thickness Overall Diameter Weight
mm² mm mm mm² mm mm mm mm mm mm kg/m
35 7 3.4 16 2.5 24 2 3.15 3.5 70 7.5
50 8.2 3.4 16 2.5 25 2 3.15 3.5 73 8.2
70 9.9 3.4 16 2.5 27 2 4 3.5 77 9.9
95 11.5 3.4 16 2.5 28 2 4 3.5 80 11.1
120 13 3.4 16 2.5 30 2 4 3.5 84 12.2
150 14.5 3.4 25 2.5 31 2 4 3.5 87 13.6
185 16.1 3.4 25 2.5 33 2 5 4 93 16.8
240 18.6 3.4 25 2.5 35 2 5 4 99 19.1

12/20(24) KV

Nominal Cross Section Area Nominal Conductor Diameter Nominal Insulation Thickness Nominal Screen Cross Section Area Nominal Core Sheath Thickness Nominal Core Diameter Nominal Bedding Thickness Nominal Steel Wire Diameter Serving Thickness Overall Diameter Weight
mm² mm mm mm² mm mm mm mm mm mm kg/m
35 7 5.5 16 2.5 28 2 3.15 3.5 78 8.8
50 8.2 5.5 16 2.5 30 2 3.15 3.5 83 9.3
70 9.9 5.5 16 2.5 31 2 4 3.5 87 11.4
95 11.5 5.5 16 2.5 33 2 4 3.5 89 12.7
120 13 5.5 16 2.5 34 2 4 4 94 14.1
150 14.5 5.5 25 2.5 36 2 4 4 97 15.3
185 16.1 5.5 25 2.5 37 2 5 4 102 18.6
240 18.6 5.5 25 2.5 40 2 5 4 108 21.1

18/30(36) KV

Nominal Cross Section Area Nominal Conductor Diameter Nominal Insulation Thickness Nominal Screen Cross Section Area Nominal Core Sheath Thickness Nominal Core Diameter Nominal Bedding Thickness Nominal Steel Wire Diameter Serving Thickness Overall Diameter Weight
mm² mm mm mm² mm mm mm mm mm mm kg/m
50 8.2 8 16 2.5 35 2 3.15 3.5 93 11.1
70 9.9 8 16 2.5 36 2 4 4 99 12.8
95 11.5 8 16 2.5 38 2 4 4 102 14.9
120 13 8 16 2.5 39 2 4 4 105 16.2
150 14.5 8 25 2.5 41 2 4 4 108 17.6
185 16.1 8 25 2.5 42 2 5 4 113 21
240 18.6 8 25 2.5 45 2 5 4 119 23.4

Additional information

Brand

ZMS CABLE